Fixed Installation (C125-TINO-INN)
DANGER:
By law, only authorized electricians are allowed to install the Control Unit.
Make sure that the power to the stove is disconnected before and during the entire installation.
Do not switch on the power from the electrical panel before you have made sure that the Sensor Unit and the Control Unit are set and ready for a function test.
- Switch off power to the stove from the electrical panel.
- Remove the knock-out lid and pull the wires through the opening.
It is possible to remove the knock-out lid either at the back (Option A) or at the side (Option B) of the Control Unit.
Option A
Option B
- Strip 10 mm from the end of all the wires (PE, L, N).
- Place the Control Unit onto the screws with the socket pointing down or to the
left.
It is also possible to connect the Control Unit to a kitchen cabinet or a wall.
Option A
Option B
- Twist the Control Unit to lock it in place and tighten the screws.
Make sure that the Control Unit is completely covering the opening on the wall.
-
Connect the wires using one of the following
diagrams. Use a PH2 screwdriver for all connections.
Note: Do not overtighten the screws.
1-Phase wiring
IT-grid wiring
- To close the cover of the Control Unit, insert the two teeth into their slots
and press the cover against the unit. The lock near the socket outlet clicks
when closed.Note: To open the cover, press the clip on the cover with an 8mm flat head screwdriver or similar tool.Warning: Never open the cover when the power is connected.
- Connect the stove power plug.Note: Make sure that the plug is properly plugged in.
- Switch on the power to the stove from the electrical panel.Note: If the installation location is anything other than the default (installation height 50 - 60 cm above the cooktop), set the correct installation zone. See Changing the Installation Zone for more information.